Endurance Energy 12V 24Ah 230A EN Flat Lug Starter Battery (RH Positive) - Part Number: 5796U1R9
The Endurance Energy 12V 24Ah (230A EN cold cranking) compact starter battery (part number 5796U1R9, OEM cross-references GB U1R-48M-IDX, 714446, 682417, U1-9R SMF12V/32AH SMF CA/CA, U19RSMF12V32AHSMFCACA, GBU1R48MIDX, right-hand positive counterpart to 5796U1L9) is an authentic high-performance starting accumulator engineered for ride-on lawnmowers, professional groundcare equipment, motor cultivators, Zero-Turn mowers, and portable generators. Built on heavy-duty SLI (Starting, Lighting, Ignition) architecture, it features specialized bolt-through flat lug terminals arranged in standard Layout 0 polarity (- / +, positive terminal on the right), ensuring a perfect direct-fit connection to equipment factory wiring harnesses without cable strain. Built with standard U1R case dimensions of 195 x 130 x 183 mm, a smooth B00 base (designed for top hold-down bracket clamping), and an EN 50342 class V2 vibration resistance rating, it protects internal plate packs against severe mowing deck vibration and rough terrain shocks.
Key Features & Engineering Advantages
- Optimized Cold Cranking Output (230A EN): Substantial instantaneous discharge power concentrated in a compact casing, delivering crisp and reliable engine starts on petrol and small diesel utility engines even after extended winter downtime.
- Bolt-Through Flat Lug Terminals: Engineered flat contact posts with pre-drilled bolt eyelet holes, ensuring a vibration-proof electrical bond that prevents arcing and terminal loosening.
- Standard Polarity Layout 0 (- / + Positive on the Right): Standard U1R terminal layout configured to match factory wiring harnesses on groundcare and utility equipment requiring a right-hand positive post.
- Class V2 Vibration Resistance (EN Standard): Specially anchored internal plate groups designed to absorb high-frequency engine pulses and continuous deck shocks during commercial turf-mowing cycles.
- Smooth B00 Base Ledge: Clean, flat-bottom casing design engineered for seamless drop-in installation into battery trays secured by top hold-down brackets.
Technical Specifications
| Commercial Part Number |
5796U1R9 |
| OEM References & Cross-Codes |
GB U1R-48M-IDX, 714446, 682417, U1-9R SMF12V/32AH SMF CA/CA, U19RSMF12V32AHSMFCACA, GBU1R48MIDX |
| Brand / Product Range |
Endurance Energy |
| Nominal Voltage |
12 V |
| Nominal Capacity (Ah) |
24 Ah |
| Cold Cranking Amps (CCA) |
230 A (EN rating) |
| Battery Classification |
SLI (Starting, Lighting, Ignition) |
| Terminal Type |
Flat Lug (with bolt-through hole) |
| Circuit / Polarity Layout |
Layout 0 (Positive on the right – RH) • Terminal sequence: - / + |
| Base Hold-Down Type |
B00 (flat bottom without lower ledges, top-clamp secured) |
| Vibration Resistance |
Class V2 (in accordance with EN 50342) |
| External Dimensions (L x W x H) |
195 x 130 x 183 mm |
Recommended Applications
| Operational Sector |
Compatible Machinery & Applications |
| Commercial Lawn & Groundcare |
Ride-on mowers, front mowers, riders, and Zero-Turn mowers configured for U1R case size with right-hand positive terminals |
| Compact Agricultural Equipment |
Two-wheel tractors, motorized barrows, sickle bar mowers, and compact two-stage snow blowers with 12V electric start |
| Stationary & Construction Equipment |
Portable petrol/diesel generator sets, irrigation water pumps, and compact compaction plates |
Hazard Warnings & Safety Measures (CLP Regulation): DANGER: Contains corrosive battery acid and lead components. Harmful if inhaled. Causes severe skin burns and serious eye damage. Suspected of causing genetic defects.
• Prevention: Do not breathe dust/fume/gas/mist/vapours/spray. Use only outdoors or in a well-ventilated area. Wash hands thoroughly after handling. Wear protective gloves, protective clothing, eye protection, and face protection (mandatory PPE). Do not eat, drink, or smoke when using this product.
• Emergency Response: IF INHALED: Remove person to fresh air and keep comfortable for breathing; call a Poison Center or doctor if you feel unwell. IF SWALLOWED: Rinse mouth; do NOT induce vomiting; immediately call a Poison Center or doctor. IF ON SKIN (or hair): Take off immediately all contaminated clothing; rinse skin with water or shower; wash contaminated clothing before reuse. IF IN EYES: Rinse cautiously with water for several minutes; remove contact lenses if present and easy to do; continue rinsing.
• Storage & Disposal: Store in a well-ventilated place. Dispose of contents and container in accordance with local, regional, and national hazardous waste regulations.
Installation Advice & Workshop Notes: Before installation, confirm the compartment dimensions (195x130x183 mm) and check the Layout 0 polarity scheme (positive terminal on the right). Turn off the equipment ignition switch; disconnect the negative cable (-) first, then the positive cable (+). Clean the mounting tray of grass clippings and debris, seat the battery onto the flat B00 base, and securely fasten the top hold-down bracket to prevent displacement during operation. Connect the flat lug terminals using clean bolts: attach the positive cable (+) first, followed by the negative cable (-), and coat connections with technical petroleum jelly to guard against corrosion. During winter storage periods, disconnect leads or connect to a 12V smart maintenance trickle charger in a dry, ventilated area.